Characteristics:
Continued gentle radial tensile force,effectively expands the stenosis,reducing the patients’ discomfort.
Imaging markers of the stents are clear visible under image equipment.Positioning is more accurate.
With bundled transmission mode.
Introducer system sketch:

specification table:
|
Stents diameter(mm) |
Length(mm) |
Description |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
|
16 |
40/50/60 |
1.
|
24r× 700 |
|
18 |
40/50/60 |
24r× 700 |
|
|
20 |
40/50/60 |
24r× 700 |
|
|
22 |
40/50/60 |
24r× 700 |
J- Trachea/Bronchus stent
Usage :
Used to ease of malignant lesions caused by primary tracheal and bronchial stenosis .
Characteristics:
Continued gentle radial tensile force,effectively expands the stenosis,reducing the patients’ discomfort.
Full compliance with the anatomical knot of tracheal bifurcation .
Imaging markers of the stents are clear visible under image equipment.Positioning is more accurate.
Introducer system sketch:

specification table
|
Stents diameter(mm) |
Length(mm) |
Description |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
|
18 |
40/50/60/70/80 |
1. Regular size of left bronchus –Diameter:12/14mm,Length: 20/25/30/35mm 2. Regular size of right bronchus –Diameter:12/14mm, Length:10/15/20/25mm
|
push-based introducer system:8×600 |
|
20 |
40/50/60/70/80 |
||
|
22 |
40/50/60/70/80 |
Product detail pictures:



Related Product Guide:
SpectraScience (OTCMKTS:SCIE) vs. CHF Solutions (OTCMKTS:CHFS) Financial Survey | Cylindrical Anoscope
Seeded Amplification of Chronic Wasting Disease Prions in Nasal Brushings and Recto-anal Mucosa-Associated Lymphoid Tissues from Elk by Real-Time Quaking-Induced Conversion | Cytology Brush
All we do is often involved with our tenet " Purchaser to start with, Rely on initially, devoting over the food stuff packaging and environmental defense for 2017 New Style Metal Clip For Endoscopy - Trachea Bronchus Stent – Chenmao, The product will supply to all over the world, such as: San Francisco , Madagascar , Johannesburg , With more and more Chinese products and solutions around the world, our international business is developing rapidly and economic indicators big increase year by year. We have enough confidence to supply you both better solutions and service, because we've been more and more powerful, specialist and experience in domestic and international.
Wide range, good quality, reasonable prices and good service, advanced equipment, excellent talents and continuously strengthened technology forces,a nice business partner.