factory low price Spray Pipe - High Performance Medical Human Implant Intestinal Stent Surgical Self Expandable Metal Colon Stent – Chenmao
factory low price Spray Pipe - High Performance Medical Human Implant Intestinal Stent Surgical Self Expandable Metal Colon Stent – Chenmao Detail:
We’re commitment to offer you the competitive price ,remarkable products excellent, also as fast delivery for High Performance Medical Human Implant Intestinal Stent Surgical Self Expandable Metal Colon Stent, Never-ending improvement and striving for 0% deficiency are our two main good quality policies. Should you need anything, do not hesitate to call us.
We’re commitment to offer you the competitive price ,remarkable products excellent, also as fast delivery for Human Implant, Intestinal Stent Nitinol, Self Expandable Metal Stent, We follow up the career and aspiration of our elder generation, and we’ve been eager to open up a new prospect in this field, We insist on “Integrity, Profession, Win-win Cooperation”, because we now have a strong backup, that are excellent partners with advanced manufacturing lines, abundant technical strength, standard inspection system and good production capacity.
Characteristics:
Continued gentle radial tensile force,effectively expands the stenosis,reducing the patients’ discomfort.
Imaging markers of the stents are clear visible under image equipment.Positioning is more accurate.
Conform to the pylorus of physiological anatomy port design
Introducer system sketch:
specification table:
Stent diameter(mm) |
(mm) Port diameter |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
Head end shape |
18 |
18/45 |
60/80 |
18Fr× 1350 |
Single ball-single horn |
20 |
20/45 |
60/80 |
18Fr× 1350 |
|
18 |
18/45 |
60/80 |
18Fr× 1350 |
Double horns |
20 |
20/45 |
60/80 |
18Fr× 1350 |
|
18 |
18/45 |
60/80 |
18Fr× 1350 |
Double balls |
20 |
20/45 |
60/80 |
18Fr× 1350 |
Stent diameter(mm) |
Port diameter (middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
18 |
18/25 |
60/80/100/120 |
18Fr× 1300(OTW) |
20 |
20/25 |
60/80/100/120 |
18Fr× 1300(OTW) |
18 |
18/25 |
60/80/100 |
10Fr× 1800(TTS) |
20 |
20/25 |
60/80/100 |
10Fr× 1800(TTS) |
Stent diameter(mm) |
Port diameter(middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
25 |
25/36 |
60/80/100 |
24Fr× 1000(OTW) |
28 |
28/36 |
60/80/100 |
24Fr× 1000(OTW) |
30 |
30/36 |
60/80/100 |
24Fr× 1000(OTW) |
25 |
25/36 |
60/80/100 |
10Fr× 2400(TTS) |
28 |
28/36 |
60/80/100 |
10Fr× 2400(TTS) |
30 |
30/36 |
60/80/100 |
10Fr× 2400(TTS) |
Stent diameter(mm) |
Port diameter(middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
28 |
28/36 |
60/80/100 |
24Fr× 1000(OTW) |
30 |
30/36 |
60/80/100 |
24Fr× 1000(OTW) |
Product detail pictures:

Related Product Guide:
Promising Technologies Arise for Diagnosis of Barrett’s Esophagus | Hemorrhoidal Circular Stapler
Better wound sealing with a hot-glue gun | Wound Closure Device
we can offer high quality products, competitive price and best customer service. Our destination is "You come here with difficulty and we give you a smile to take away" for factory low price Spray Pipe - High Performance Medical Human Implant Intestinal Stent Surgical Self Expandable Metal Colon Stent – Chenmao, The product will supply to all over the world, such as: Bogota , Cologne , Ghana , Our next goal is to exceed the expectations of every client by offering outstanding customer service, increased flexibility and greater value. All in all, without our customers we do not exist; without happy and fully satisfied customers, we fail. We are looking for the wholesale, Drop ship. Please contact us if you are interesting our products. Hope to do business with you all. High quality and fast shipment!

In our cooperated wholesalers, this company has the best quality and reasonable price, they are our first choice.
