Factory making Urethral Dilation - High Performance Medical Human Implant Intestinal Stent Surgical Self Expandable Metal Colon Stent – Chenmao

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We constantly believe that one's character decides products' high quality, the details decides products' high-quality ,together with the REALISTIC,EFFICIENT AND INNOVATIVE crew spirit for Gastroscope Bite Block , Endoscopic Hemoclip , Mouth Guard , We adhere to the tenet of "Services of Standardization, to Meet Customers' Demands".
Factory making Urethral Dilation - High Performance Medical Human Implant Intestinal Stent Surgical Self Expandable Metal Colon Stent – Chenmao Detail:

We’re commitment to offer you the competitive price ,remarkable products excellent, also as fast delivery for High Performance Medical Human Implant Intestinal Stent Surgical Self Expandable Metal Colon Stent, Never-ending improvement and striving for 0% deficiency are our two main good quality policies. Should you need anything, do not hesitate to call us.
We’re commitment to offer you the competitive price ,remarkable products excellent, also as fast delivery for Human Implant, Intestinal Stent Nitinol, Self Expandable Metal Stent, We follow up the career and aspiration of our elder generation, and we’ve been eager to open up a new prospect in this field, We insist on “Integrity, Profession, Win-win Cooperation”, because we now have a strong backup, that are excellent partners with advanced manufacturing lines, abundant technical strength, standard inspection system and good production capacity.
Characteristics:
Continued gentle radial tensile force,effectively expands the stenosis,reducing the patients’ discomfort.
Imaging markers of the stents are clear visible under image equipment.Positioning is more accurate.
Conform to the pylorus of physiological anatomy port design
Introducer system sketch:
otw
specification table:

Stent diameter(mm)

(mm)

Port diameter
(middle/near-end)

Length(mm)

Specification of Introducer system

(Pipe diameter Fr × effective working length   mm)

Head end shape

18

18/45

60/80

18Fr× 1350

Single ball-single horn

20

20/45

60/80

18Fr× 1350

18

18/45

60/80

18Fr× 1350

Double horns

20

20/45

60/80

18Fr× 1350

18

18/45

60/80

18Fr× 1350

Double balls

20

20/45

60/80

18Fr× 1350

 

Stent diameter(mm)

Port diameter (middle/near-end)

Length(mm)

Specification of Introducer system

(Pipe diameter Fr × effective working length   mm)

18

18/25

60/80/100/120

18Fr× 1300(OTW)

20

20/25

60/80/100/120

18Fr× 1300(OTW)

18

18/25

60/80/100

10Fr× 1800(TTS)

20

20/25

60/80/100

10Fr× 1800(TTS)

 

Stent diameter(mm)

Port diameter(middle/near-end)

Length(mm)

Specification of Introducer system

(Pipe diameter Fr × effective working length   mm)

25

25/36

60/80/100

24Fr× 1000(OTW)

28

28/36

60/80/100

24Fr× 1000(OTW)

30

30/36

60/80/100

24Fr× 1000(OTW)

25

25/36

60/80/100

10Fr× 2400(TTS)

28

28/36

60/80/100

10Fr× 2400(TTS)

30

30/36

60/80/100

10Fr× 2400(TTS)

 

Stent diameter(mm)

Port diameter(middle/near-end)

Length(mm)

Specification of Introducer system

(Pipe diameter Fr × effective working length   mm)

28

28/36

60/80/100

24Fr× 1000(OTW)

30

30/36

60/80/100

24Fr× 1000(OTW)


Product detail pictures:

Factory making Urethral Dilation -
 High Performance Medical Human Implant Intestinal Stent Surgical Self Expandable Metal Colon Stent – Chenmao detail pictures


Related Product Guide:
Biopsy Forceps Market Size, Market Opportunities, SWOT Analysis, Key Players and Forecast to 2024 | Wound Closure Device
Mining Tire Market Report – A Complete Overview of Market Segments and the Regional Outlook of Mining Tire Industry | Cytology Brush

abide by the contract", conforms to the market requirement, joins during the market competition by its superior quality also as provides extra comprehensive and exceptional service for consumers to let them turn into significant winner. The pursue of the business, is definitely the clients' gratification for Factory making Urethral Dilation - High Performance Medical Human Implant Intestinal Stent Surgical Self Expandable Metal Colon Stent – Chenmao, The product will supply to all over the world, such as: Doha , Israel , Uzbekistan , Certainly, competitive price, suitable package and timely delivery will be assured as per customers' demands. We sincerely hope to build business relationship with you on the basis of mutual benefit and profit in the very near future. Warmly welcome to contact us and become our direct cooperators.
  • Company director has very rich management experience and strict attitude, sales staff are warm and cheerful, technical staff are professional and responsible,so we have no worry about product,a nice manufacturer.
    5 Stars By Margaret from Nairobi - 2018.06.03 10:17
    The goods we received and the sample sales staff display to us have the same quality, it is really a creditable manufacturer.
    5 Stars By Katherine from Barbados - 2017.01.28 19:59

    Related Products