Factory source Hemorrhoid Band Ligator - Intestinal Stent – Chenmao
Factory source Hemorrhoid Band Ligator - Intestinal Stent – Chenmao Detail:
Characteristics:
Continued gentle radial tensile force,effectively expands the stenosis,reducing the patients’ discomfort.
Imaging markers of the stents are clear visible under image equipment.Positioning is more accurate.
Conform to the pylorus of physiological anatomy port design
Introducer system sketch:
specification table:
Stent diameter(mm) |
(mm) Port diameter |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
Head end shape |
18 |
18/45 |
60/80 |
18Fr× 1350 |
Single ball-single horn |
20 |
20/45 |
60/80 |
18Fr× 1350 |
|
18 |
18/45 |
60/80 |
18Fr× 1350 |
Double horns |
20 |
20/45 |
60/80 |
18Fr× 1350 |
|
18 |
18/45 |
60/80 |
18Fr× 1350 |
Double balls |
20 |
20/45 |
60/80 |
18Fr× 1350 |
Stent diameter(mm) |
Port diameter (middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
18 |
18/25 |
60/80/100/120 |
18Fr× 1300(OTW) |
20 |
20/25 |
60/80/100/120 |
18Fr× 1300(OTW) |
18 |
18/25 |
60/80/100 |
10Fr× 1800(TTS) |
20 |
20/25 |
60/80/100 |
10Fr× 1800(TTS) |
Stent diameter(mm) |
Port diameter(middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
25 |
25/36 |
60/80/100 |
24Fr× 1000(OTW) |
28 |
28/36 |
60/80/100 |
24Fr× 1000(OTW) |
30 |
30/36 |
60/80/100 |
24Fr× 1000(OTW) |
25 |
25/36 |
60/80/100 |
10Fr× 2400(TTS) |
28 |
28/36 |
60/80/100 |
10Fr× 2400(TTS) |
30 |
30/36 |
60/80/100 |
10Fr× 2400(TTS) |
Stent diameter(mm) |
Port diameter(middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
28 |
28/36 |
60/80/100 |
24Fr× 1000(OTW) |
30 |
30/36 |
60/80/100 |
24Fr× 1000(OTW) |
Product detail pictures:

Related Product Guide:
SpectraScience (OTCMKTS:SCIE) vs. CHF Solutions (OTCMKTS:CHFS) Financial Survey | Cylindrical Anoscope
Middle East and Africa Gynaecological Devices Market Presents an All-Inclusive Development Trends, Driving Factors, Restraints, Opportunities 2017-2023 | Wound Closure Device
"Control the standard by the details, show the power by quality". Our business has strived to establish a highly efficient and stable team staff and explored an effective good quality regulate course of action for Factory source Hemorrhoid Band Ligator - Intestinal Stent – Chenmao, The product will supply to all over the world, such as: Kuala Lumpur , Kenya , Singapore , All the employees in factory, store, and office are struggling for one common goal to provide better quality and service. Real business is to get win-win situation. We would like to provide more support for customers. Welcome all nice buyers to communicate details of our products with us!

It can be said that this is a best producer we encountered in China in this industry, we feel lucky to work with so excellent manufacturer.