Good quality Surgical Ligating Clip - Intestinal Stent – Chenmao
Good quality Surgical Ligating Clip - Intestinal Stent – Chenmao Detail:
Characteristics:
Continued gentle radial tensile force,effectively expands the stenosis,reducing the patients’ discomfort.
Imaging markers of the stents are clear visible under image equipment.Positioning is more accurate.
Conform to the pylorus of physiological anatomy port design
Introducer system sketch:
specification table:
Stent diameter(mm) |
(mm) Port diameter |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
Head end shape |
18 |
18/45 |
60/80 |
18Fr× 1350 |
Single ball-single horn |
20 |
20/45 |
60/80 |
18Fr× 1350 |
|
18 |
18/45 |
60/80 |
18Fr× 1350 |
Double horns |
20 |
20/45 |
60/80 |
18Fr× 1350 |
|
18 |
18/45 |
60/80 |
18Fr× 1350 |
Double balls |
20 |
20/45 |
60/80 |
18Fr× 1350 |
Stent diameter(mm) |
Port diameter (middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
18 |
18/25 |
60/80/100/120 |
18Fr× 1300(OTW) |
20 |
20/25 |
60/80/100/120 |
18Fr× 1300(OTW) |
18 |
18/25 |
60/80/100 |
10Fr× 1800(TTS) |
20 |
20/25 |
60/80/100 |
10Fr× 1800(TTS) |
Stent diameter(mm) |
Port diameter(middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
25 |
25/36 |
60/80/100 |
24Fr× 1000(OTW) |
28 |
28/36 |
60/80/100 |
24Fr× 1000(OTW) |
30 |
30/36 |
60/80/100 |
24Fr× 1000(OTW) |
25 |
25/36 |
60/80/100 |
10Fr× 2400(TTS) |
28 |
28/36 |
60/80/100 |
10Fr× 2400(TTS) |
30 |
30/36 |
60/80/100 |
10Fr× 2400(TTS) |
Stent diameter(mm) |
Port diameter(middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
28 |
28/36 |
60/80/100 |
24Fr× 1000(OTW) |
30 |
30/36 |
60/80/100 |
24Fr× 1000(OTW) |
Product detail pictures:

Related Product Guide:
Global Urology Devices Market Set to Grow at Healthy CAGR By 2026 | Medtronic, Siemens AG, Baxter, B. Braun Melsungen AG, Fresenius Medical Care AG & Co. KGaA, Karl Storz GmbH & Co. Kg, Stryker, Olympus Corporation, Cook Group, C.R. Bard, Inc. | Cytology Brush
How to treat the pain and discomfort of haemorrhoids The A to Z of one of pregnancy’s more unpleasant side effects | Wound Closure Device
Innovation, excellent and reliability are the core values of our firm. These principles today more than ever form the basis of our success as an internationally active mid-size corporation for Good quality Surgical Ligating Clip - Intestinal Stent – Chenmao, The product will supply to all over the world, such as: Argentina , UK , New York , Our products are mainly exported to Europe, Africa, America, the Middle East and Southeast Asia and other countries and regions. We have enjoyed a great reputation among our customers for quality products and good services.We would make friends with businessmen from at home and abroad, following the purpose of "Quality First, Reputation First, the Best Services."

Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.
