Manufacturer for Endoscopic Retrieve - Bougie dilator – Chenmao
Manufacturer for Endoscopic Retrieve - Bougie dilator – Chenmao Detail:
Characteristic
- 1.The dilator is made of medical-grade polymer materials with moderate hardness
- 2.The end cone is smooth,conductive to expansion,and less traumatic.
- 3.There is a developing ring at the head end,which can be positioned more accurately under X-way.
- 4.Comes with a portable outer box for easy transportation .
Product Properties
1.The surface of bougie shall be smooth without burr, as well as the front con.
2.The guide wire body shall pass through the inner hole of the bougie without blocking.
3.The bougie with development rings shall have X-ray development markings.
4.Appearance (turbidity, color) : colorless transparent, visually no foreign body.
Specifications
|
Model Number |
Diameter(mm) |
Length(mm) |
|
GM-BD-A1-05-850 |
5 |
850 |
|
GM-BD-A1-06-850 |
6 |
850 |
|
GM-BD-A1-07-850 |
7 |
850 |
|
GM-BD-A1-08-850 |
8 |
850 |
|
GM-BD-A1-09-850 |
9 |
850 |
|
GM-BD-A1-10-850 |
10 |
850 |
|
GM-BD-A1-11-850 |
11 |
850 |
|
GM-BD-A1-12-850 |
12 |
850 |
|
GM-BD-A1-13-850 |
13 |
850 |
|
GM-BD-A1-14-850 |
14 |
850 |
|
GM-BD-A1-15-850 |
15 |
850 |
|
GM-BD-A1-16-850 |
16 |
850 |
|
GM-BD-A1-17-850 |
17 |
850 |
|
GM-BD-A1-18-850 |
18 |
850 |
|
GM-BD-A1-19-850 |
19 |
850 |
|
GM-BD-A1-20-850 |
20 |
850 |
Disposable cytology brush structure diagram

Scope of application
The disposable bougie is indicated for patients with esophageal and cardiac stricture dilation therapy.
Contraindications
1. The device shall be thoroughly sterilized before use.
2. According to X-ray or endoscopic observation of the stenosis of the esophagus or cardia of the patient during the application, the bougie with a diameter slightly larger than that of the narrow site of patient shall be selected.
3. Under X-ray monitoring, the guide wire shall be first inserted through the hole of the gastroscope until the soft spring at the front of the guide wire was in the stomach cavity (it can be judged whether it is in the stomach from the bending shape of the soft spring), and the guide wire shall be removed from the gastroscope and retained.
4. The bougie is slid along the guide wire through the narrow part of the patient to play an expansion role. The diameter of the bougie shall be selected from small to large and gradually expanded.
Instructions For Use
Product detail pictures:



Related Product Guide:
CHF Solutions (NASDAQ:CHFS) versus SpectraScience (NASDAQ:SCIE) Financial Analysis | Endoscope Biopsy Forceps
Dock Seals and Shelters Market Breakdown, Development and New Market Opportunities & Forecasts | Hemorrhoidal Circular Stapler
Our corporation has been specializing in brand strategy. Customers' gratification is our greatest advertising. We also source OEM company for Manufacturer for Endoscopic Retrieve - Bougie dilator – Chenmao, The product will supply to all over the world, such as: Albania , Toronto , Swansea , So We also continuously function. we, focuse on high quality, and are conscious of the importance of environmental protection, most of the merchandise are pollution-free, environmentally friendly solutions, reuse on the solution. We've Updated our catalog, which introduces our organization. n detail and covers the primary products we provide at present, You may also visit our web-site, which involves our most recent product line. We look forward to reactivating our company connection.
Superb technology, perfect after-sales service and efficient work efficiency, we think this is our best choice.