OEM/ODM Factory Surgery Disposable Titanium Clip - High Performance Medical Human Implant Intestinal Stent Surgical Self Expandable Metal Colon Stent – Chenmao
OEM/ODM Factory Surgery Disposable Titanium Clip - High Performance Medical Human Implant Intestinal Stent Surgical Self Expandable Metal Colon Stent – Chenmao Detail:
We’re commitment to offer you the competitive price ,remarkable products excellent, also as fast delivery for High Performance Medical Human Implant Intestinal Stent Surgical Self Expandable Metal Colon Stent, Never-ending improvement and striving for 0% deficiency are our two main good quality policies. Should you need anything, do not hesitate to call us.
We’re commitment to offer you the competitive price ,remarkable products excellent, also as fast delivery for Human Implant, Intestinal Stent Nitinol, Self Expandable Metal Stent, We follow up the career and aspiration of our elder generation, and we’ve been eager to open up a new prospect in this field, We insist on “Integrity, Profession, Win-win Cooperation”, because we now have a strong backup, that are excellent partners with advanced manufacturing lines, abundant technical strength, standard inspection system and good production capacity.
Characteristics:
Continued gentle radial tensile force,effectively expands the stenosis,reducing the patients’ discomfort.
Imaging markers of the stents are clear visible under image equipment.Positioning is more accurate.
Conform to the pylorus of physiological anatomy port design
Introducer system sketch:

specification table:
|
Stent diameter(mm) |
(mm) Port diameter |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
Head end shape |
|
18 |
18/45 |
60/80 |
18Fr× 1350 |
Single ball-single horn |
|
20 |
20/45 |
60/80 |
18Fr× 1350 |
|
|
18 |
18/45 |
60/80 |
18Fr× 1350 |
Double horns |
|
20 |
20/45 |
60/80 |
18Fr× 1350 |
|
|
18 |
18/45 |
60/80 |
18Fr× 1350 |
Double balls |
|
20 |
20/45 |
60/80 |
18Fr× 1350 |
|
Stent diameter(mm) |
Port diameter (middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
|
18 |
18/25 |
60/80/100/120 |
18Fr× 1300(OTW) |
|
20 |
20/25 |
60/80/100/120 |
18Fr× 1300(OTW) |
|
18 |
18/25 |
60/80/100 |
10Fr× 1800(TTS) |
|
20 |
20/25 |
60/80/100 |
10Fr× 1800(TTS) |
|
Stent diameter(mm) |
Port diameter(middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
|
25 |
25/36 |
60/80/100 |
24Fr× 1000(OTW) |
|
28 |
28/36 |
60/80/100 |
24Fr× 1000(OTW) |
|
30 |
30/36 |
60/80/100 |
24Fr× 1000(OTW) |
|
25 |
25/36 |
60/80/100 |
10Fr× 2400(TTS) |
|
28 |
28/36 |
60/80/100 |
10Fr× 2400(TTS) |
|
30 |
30/36 |
60/80/100 |
10Fr× 2400(TTS) |
|
Stent diameter(mm) |
Port diameter(middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
|
28 |
28/36 |
60/80/100 |
24Fr× 1000(OTW) |
|
30 |
30/36 |
60/80/100 |
24Fr× 1000(OTW) |
Product detail pictures:

Related Product Guide:
Seeded Amplification of Chronic Wasting Disease Prions in Nasal Brushings and Recto-anal Mucosa-Associated Lymphoid Tissues from Elk by Real-Time Quaking-Induced Conversion | Cytology Brush
Global Tissue Engineering Market to 2024 | Wound Closure Device
Our intention is usually to satisfy our buyers by offering golden provider, great rate and good quality for OEM/ODM Factory Surgery Disposable Titanium Clip - High Performance Medical Human Implant Intestinal Stent Surgical Self Expandable Metal Colon Stent – Chenmao, The product will supply to all over the world, such as: Yemen , Nepal , USA , The credibility is the priority, and the service is the vitality. We promise we have the ability to provide excellent quality and reasonable price products for customers. With us, your safety is guaranteed.
This supplier stick to the principle of "Quality first, Honesty as base", it is absolutely to be trust.




