Popular Design for Disposable Endoscopic Stone Extractor - Intestinal Stent – Chenmao
Popular Design for Disposable Endoscopic Stone Extractor - Intestinal Stent – Chenmao Detail:
Characteristics:
Continued gentle radial tensile force,effectively expands the stenosis,reducing the patients’ discomfort.
Imaging markers of the stents are clear visible under image equipment.Positioning is more accurate.
Conform to the pylorus of physiological anatomy port design
Introducer system sketch:

specification table:
|
Stent diameter(mm) |
(mm) Port diameter |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
Head end shape |
|
18 |
18/45 |
60/80 |
18Fr× 1350 |
Single ball-single horn |
|
20 |
20/45 |
60/80 |
18Fr× 1350 |
|
|
18 |
18/45 |
60/80 |
18Fr× 1350 |
Double horns |
|
20 |
20/45 |
60/80 |
18Fr× 1350 |
|
|
18 |
18/45 |
60/80 |
18Fr× 1350 |
Double balls |
|
20 |
20/45 |
60/80 |
18Fr× 1350 |
|
Stent diameter(mm) |
Port diameter (middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
|
18 |
18/25 |
60/80/100/120 |
18Fr× 1300(OTW) |
|
20 |
20/25 |
60/80/100/120 |
18Fr× 1300(OTW) |
|
18 |
18/25 |
60/80/100 |
10Fr× 1800(TTS) |
|
20 |
20/25 |
60/80/100 |
10Fr× 1800(TTS) |
|
Stent diameter(mm) |
Port diameter(middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
|
25 |
25/36 |
60/80/100 |
24Fr× 1000(OTW) |
|
28 |
28/36 |
60/80/100 |
24Fr× 1000(OTW) |
|
30 |
30/36 |
60/80/100 |
24Fr× 1000(OTW) |
|
25 |
25/36 |
60/80/100 |
10Fr× 2400(TTS) |
|
28 |
28/36 |
60/80/100 |
10Fr× 2400(TTS) |
|
30 |
30/36 |
60/80/100 |
10Fr× 2400(TTS) |
|
Stent diameter(mm) |
Port diameter(middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
|
28 |
28/36 |
60/80/100 |
24Fr× 1000(OTW) |
|
30 |
30/36 |
60/80/100 |
24Fr× 1000(OTW) |
Product detail pictures:

Related Product Guide:
J&J posts $27B in 2018 medical device sales in slight bump | Cylindrical Anoscope
Field Validation of SYBR Green- and TaqMan-Based Real-Time PCR Using Biopsy and Swab Samples To Diagnose American Tegumentary Leishmaniasis in an Area Where Leishmania (Viannia) braziliensis Is Endemic | Hemorrhoidal Circular Stapler
Our well-equipped facilities and great excellent command throughout all stages of generation enables us to guarantee total customer fulfillment for Popular Design for Disposable Endoscopic Stone Extractor - Intestinal Stent – Chenmao, The product will supply to all over the world, such as: Rotterdam , Latvia , Somalia , We pay high attention to customer service, and cherish every customer. We have maintained a strong reputation in the industry for many years. We are honest and work on building a long-term relationship with our customers.
Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.




