We’re commitment to offer you the competitive price ,remarkable products excellent, also as fast delivery for High Performance Medical Human Implant Intestinal Stent Surgical Self Expandable Metal Colon Stent, Never-ending improvement and striving for 0% deficiency are our two main good quality policies. Should you need anything, do not hesitate to call us.
We’re commitment to offer you the competitive price ,remarkable products excellent, also as fast delivery for Human Implant, Intestinal Stent Nitinol, Self Expandable Metal Stent, We follow up the career and aspiration of our elder generation, and we’ve been eager to open up a new prospect in this field, We insist on “Integrity, Profession, Win-win Cooperation”, because we now have a strong backup, that are excellent partners with advanced manufacturing lines, abundant technical strength, standard inspection system and good production capacity.
Characteristics:
Continued gentle radial tensile force,effectively expands the stenosis,reducing the patients’ discomfort.
Imaging markers of the stents are clear visible under image equipment.Positioning is more accurate.
Conform to the pylorus of physiological anatomy port design
Introducer system sketch:

specification table:
|
Stent diameter(mm) |
(mm) Port diameter |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
Head end shape |
|
18 |
18/45 |
60/80 |
18Fr× 1350 |
Single ball-single horn |
|
20 |
20/45 |
60/80 |
18Fr× 1350 |
|
|
18 |
18/45 |
60/80 |
18Fr× 1350 |
Double horns |
|
20 |
20/45 |
60/80 |
18Fr× 1350 |
|
|
18 |
18/45 |
60/80 |
18Fr× 1350 |
Double balls |
|
20 |
20/45 |
60/80 |
18Fr× 1350 |
|
Stent diameter(mm) |
Port diameter (middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
|
18 |
18/25 |
60/80/100/120 |
18Fr× 1300(OTW) |
|
20 |
20/25 |
60/80/100/120 |
18Fr× 1300(OTW) |
|
18 |
18/25 |
60/80/100 |
10Fr× 1800(TTS) |
|
20 |
20/25 |
60/80/100 |
10Fr× 1800(TTS) |
|
Stent diameter(mm) |
Port diameter(middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
|
25 |
25/36 |
60/80/100 |
24Fr× 1000(OTW) |
|
28 |
28/36 |
60/80/100 |
24Fr× 1000(OTW) |
|
30 |
30/36 |
60/80/100 |
24Fr× 1000(OTW) |
|
25 |
25/36 |
60/80/100 |
10Fr× 2400(TTS) |
|
28 |
28/36 |
60/80/100 |
10Fr× 2400(TTS) |
|
30 |
30/36 |
60/80/100 |
10Fr× 2400(TTS) |
|
Stent diameter(mm) |
Port diameter(middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
|
28 |
28/36 |
60/80/100 |
24Fr× 1000(OTW) |
|
30 |
30/36 |
60/80/100 |
24Fr× 1000(OTW) |
Product detail pictures:

Related Product Guide:
EIT Health Headstart competition in Dublin: 13 start-ups win €50k each | Endoscope Biopsy Forceps
Abdominal Closure Systems Market to Make Great Impact in Near Future by 2029 | Cylindrical Anoscope
Bear "Customer 1st, Good quality first" in mind, we work closely with our prospects and supply them with efficient and professional services for Short Lead Time for Endoscopic Bag - High Performance Medical Human Implant Intestinal Stent Surgical Self Expandable Metal Colon Stent – Chenmao, The product will supply to all over the world, such as: Comoros , Bahrain , Angola , We've been persisting in the business essence "Quality First, Honoring Contracts and Standing by Reputations, providing customers with satisfying products and service. " Friends both at home and abroad are warmly welcome to establish everlasting business relations with us.
Wide range, good quality, reasonable prices and good service, advanced equipment, excellent talents and continuously strengthened technology forces,a nice business partner.