Trending ProductsEndoscopic Retrieval Bag - Disposable Endoscopic Biopsy Forceps – Chenmao
Trending ProductsEndoscopic Retrieval Bag - Disposable Endoscopic Biopsy Forceps – Chenmao Detail:
Characteristic
Injection needle is intended for submucosal injection in digestive tract combined with endoscope.
Advantage
- 1.Special sharpness treatment on jaws,proper sampling capacity without slipping.
- 2.Coating design,effectively avoid damage to the working channel.
- 3.Fine polished cups without any shart angle,effectively decrease the friction to the working channel
- 4.Laser welding tech,reliable links within each component
- 5.Excellent properties with high strength and stability
Scope of application
The disposable bougie is indicated for patients with esophageal and cardiac stricture dilation therapy.
Contraindications
1. Patient with acute perforation of esophagus, stomach and duodenum.
2. Patient with serious heart, lung, kidney, brain dysfunction and multiple organ failure.
3. Do NOT use for the patient with high risk in sampling of clinical assessment.
4. Other specific condition of the patient should be judged by professional doctor.
Specifications
|
Model Number |
Diameter(mm) |
Length(mm) |
|
GM-BD-A1-05-850 |
5 |
850 |
|
GM-BD-A1-06-850 |
6 |
850 |
|
GM-BD-A1-07-850 |
7 |
850 |
|
GM-BD-A1-08-850 |
8 |
850 |
|
GM-BD-A1-09-850 |
9 |
850 |
|
GM-BD-A1-10-850 |
10 |
850 |
|
GM-BD-A1-11-850 |
11 |
850 |
|
GM-BD-A1-12-850 |
12 |
850 |
|
GM-BD-A1-13-850 |
13 |
850 |
|
GM-BD-A1-14-850 |
14 |
850 |
|
GM-BD-A1-15-850 |
15 |
850 |
|
GM-BD-A1-16-850 |
16 |
850 |
|
GM-BD-A1-17-850 |
17 |
850 |
|
GM-BD-A1-18-850 |
18 |
850 |
|
GM-BD-A1-19-850 |
19 |
850 |
|
GM-BD-A1-20-850 |
20 |
850 |
Disposable cytology brush structure diagram

Instructions For Use
1. The device shall be thoroughly sterilized before use.
2. According to X-ray or endoscopic observation of the stenosis of the esophagus or cardia of the patient during the application, the bougie with a diameter slightly larger than that of the narrow site of patient shall be selected.
3. Under X-ray monitoring, the guide wire shall be first inserted through the hole of the gastroscope until the soft spring at the front of the guide wire was in the stomach cavity (it can be judged whether it is in the stomach from the bending shape of the soft spring), and the guide wire shall be removed from the gastroscope and retained.
4. The bougie is slid along the guide wire through the narrow part of the patient to play an expansion role. The diameter of the bougie shall be selected from small to large and gradually expanded.
Product detail pictures:



Related Product Guide:
J&J device revenue slumps amid big bet on digital surgery | Endoscope Biopsy Forceps
SpectraScience (OTCMKTS:SCIE) vs. CHF Solutions (OTCMKTS:CHFS) Financial Survey | Cylindrical Anoscope
Normally customer-oriented, and it's our ultimate concentrate on for being not only one of the most dependable, trustable and honest supplier, but also the partner for our shoppers for Trending ProductsEndoscopic Retrieval Bag - Disposable Endoscopic Biopsy Forceps – Chenmao, The product will supply to all over the world, such as: Russia , Anguilla , Japan , Really should any of these items be of interest to you, please let us know. We will be pleased to give you a quotation upon receipt of one's detailed specifications. We've our personal specialist R&D enginners to meet any of the requriements, We look forward to receiving your enquires soon and hope to have the chance to work together with you inside the future. Welcome to take a look at our organization.
The manufacturer gave us a big discount under the premise of ensuring the quality of products, thank you very much, we will select this company again.