Trending ProductsEndoscopic Retrieval Bag - High Performance Medical Human Implant Intestinal Stent Surgical Self Expandable Metal Colon Stent – Chenmao
Trending ProductsEndoscopic Retrieval Bag - High Performance Medical Human Implant Intestinal Stent Surgical Self Expandable Metal Colon Stent – Chenmao Detail:
We’re commitment to offer you the competitive price ,remarkable products excellent, also as fast delivery for High Performance Medical Human Implant Intestinal Stent Surgical Self Expandable Metal Colon Stent, Never-ending improvement and striving for 0% deficiency are our two main good quality policies. Should you need anything, do not hesitate to call us.
We’re commitment to offer you the competitive price ,remarkable products excellent, also as fast delivery for Human Implant, Intestinal Stent Nitinol, Self Expandable Metal Stent, We follow up the career and aspiration of our elder generation, and we’ve been eager to open up a new prospect in this field, We insist on “Integrity, Profession, Win-win Cooperation”, because we now have a strong backup, that are excellent partners with advanced manufacturing lines, abundant technical strength, standard inspection system and good production capacity.
Characteristics:
Continued gentle radial tensile force,effectively expands the stenosis,reducing the patients’ discomfort.
Imaging markers of the stents are clear visible under image equipment.Positioning is more accurate.
Conform to the pylorus of physiological anatomy port design
Introducer system sketch:

specification table:
|
Stent diameter(mm) |
(mm) Port diameter |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
Head end shape |
|
18 |
18/45 |
60/80 |
18Fr× 1350 |
Single ball-single horn |
|
20 |
20/45 |
60/80 |
18Fr× 1350 |
|
|
18 |
18/45 |
60/80 |
18Fr× 1350 |
Double horns |
|
20 |
20/45 |
60/80 |
18Fr× 1350 |
|
|
18 |
18/45 |
60/80 |
18Fr× 1350 |
Double balls |
|
20 |
20/45 |
60/80 |
18Fr× 1350 |
|
Stent diameter(mm) |
Port diameter (middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
|
18 |
18/25 |
60/80/100/120 |
18Fr× 1300(OTW) |
|
20 |
20/25 |
60/80/100/120 |
18Fr× 1300(OTW) |
|
18 |
18/25 |
60/80/100 |
10Fr× 1800(TTS) |
|
20 |
20/25 |
60/80/100 |
10Fr× 1800(TTS) |
|
Stent diameter(mm) |
Port diameter(middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
|
25 |
25/36 |
60/80/100 |
24Fr× 1000(OTW) |
|
28 |
28/36 |
60/80/100 |
24Fr× 1000(OTW) |
|
30 |
30/36 |
60/80/100 |
24Fr× 1000(OTW) |
|
25 |
25/36 |
60/80/100 |
10Fr× 2400(TTS) |
|
28 |
28/36 |
60/80/100 |
10Fr× 2400(TTS) |
|
30 |
30/36 |
60/80/100 |
10Fr× 2400(TTS) |
|
Stent diameter(mm) |
Port diameter(middle/near-end) |
Length(mm) |
Specification of Introducer system (Pipe diameter Fr × effective working length mm) |
|
28 |
28/36 |
60/80/100 |
24Fr× 1000(OTW) |
|
30 |
30/36 |
60/80/100 |
24Fr× 1000(OTW) |
Product detail pictures:

Related Product Guide:
microMend, a Novel and Time-Saving Wound Closure Device | Cylindrical Anoscope
Global Cytology Brush Market 2019-2025 | Types, Applications Analysis and Key Players | Wound Closure Device
Our items are commonly identified and trusted by customers and may fulfill continuously switching economic and social wants of Trending ProductsEndoscopic Retrieval Bag - High Performance Medical Human Implant Intestinal Stent Surgical Self Expandable Metal Colon Stent – Chenmao, The product will supply to all over the world, such as: Vancouver , Iran , Canberra , we are fully determined to control the whole supply chain so as to provide quality products at competitive price in a timely manner. We are keeping up with the advanced techniques, growing through creating more values for our clients and society.
The goods we received and the sample sales staff display to us have the same quality, it is really a creditable manufacturer.




